NEC Code Questions and Answers…..

Q. Is an over-counter light in a dwelling unit kitchen allowed to be hardwired to the smallappliance circuit?
A. The 20A, 120V small-appliance circuits required by 210.11(C)(1) must not supply outlets for luminaires or appliances [210.52(B)(2)].


Ex 1: The 20A, 120V small-appliance branch circuit can be used to supply a receptacle for an electric clock.


Ex 2: A receptacle can be connected to the small-appliance branch circuit to supply a gas-fired range, oven, or counter-mounted cooking unit.


A range hood or above the range microwave listed as a range hood must be supplied by an individual branch circuit [422.16(B)(4)(5)].ing if this circuit supplies luminaires, receptacles, or both [210.23(A)(2)], as shown in the Figure above.
All questions and answers are based on the 2008 NEC, taken from EC&M (http://ecmweb.com/nec/code_qa/)

 